What Happened
On March 6, 2025, an employee of Pulau Corporation was performing maintenance on a stationary armor target lift machine at the Clabber Creek Range on Fort Cavazos, the Army post near Killeen, Texas. According to OSHA's investigation, case number 348099391, the employee was repositioning a plywood target that the lift machine held in a raised position, and the machine had been requested to be taken offline before the work began. While he used a hand impact tool to tighten the bolts securing the repositioned target, the lift machine's arms came down and pinned him. OSHA's own case record lists the cause of death as asphyxiation from being pinned beneath the falling equipment.
KXXV and a Nexstar-syndicated report carried by Yahoo News both covered the death at the time, citing a Fort Cavazos spokesperson who identified the employee's company as Pulau Corporation, described in that reporting as a subcontractor to Lockheed Martin. Fort Cavazos Garrison Commander Col. Lakicia Stokes said in a statement that the installation was "fully cooperating with authorities as they conduct a thorough investigation into the circumstances surrounding this incident." Neither outlet named the employee or described how the death occurred; those details come only from OSHA's investigation file.
What OSHA Found
OSHA's investigation concluded that although the lift machine had reportedly been "requested to be offline," Pulau Corporation's actual lockout/tagout program failed at multiple points. Inspectors issued four Serious citations, all under 29 CFR 1910.147, the lockout/tagout standard:
- 29 CFR 1910.147(c)(4)(ii): the company's energy control procedure did not clearly and specifically spell out the scope, rules, and techniques employees were supposed to follow to control the machine's hazardous energy. - 29 CFR 1910.147(c)(5)(i): the lockout hardware, locks, tags, or other devices needed to physically isolate the machine from its energy source, was not provided. - 29 CFR 1910.147(c)(6)(i): the company had not conducted the periodic inspection of its own energy control procedure that the standard requires at least once a year. - 29 CFR 1910.147(c)(7)(i)(a): authorized employees had not received training in recognizing the hazardous energy sources they were working around.
Together, the citations describe a lockout program that existed loosely in name but not in practice: a written procedure without adequate detail, no annual check that it was being followed, missing hardware, and training gaps. Asking that a machine be "taken offline" is not the same as physically locking it out, and OSHA's findings indicate the lift arms were never actually isolated from their energy source before the employee worked near them.
Penalty and Status
OSHA's citation group for this inspection initially listed a combined penalty of $16,550. Following Pulau Corporation's contest, filed September 15, 2025, a final order was entered March 16, 2026, with the four citations carrying individual current penalties of $16,550, $0, $12,412.50, and $0, for a final total of $28,962.50. That final total is higher than the initial combined figure; OSHA's own record does not explain the increase, and this article discloses that discrepancy rather than resolving it.
Company History
No other OSHA inspection or citation on record matches the exact company name "Pulau Corporation." A different, unrelated company, Pulau Electronics Corp. of Chatsworth, California, was inspected once in 1988; nothing in the available record ties that case to this one. This appears to be Pulau Corporation's only citation history with OSHA.