What OSHA Found
OSHA cited Harlan Community Television Incorporated $122,500 across 12 citations following an inspection opened March 4, 2026 at the company's facility in Holmes Mill, Kentucky. The inspection covered a crew working on utility poles and from vehicle-mounted aerial lifts, work and equipment regulated by 29 CFR 1910.268, OSHA's dedicated Telecommunications standard, and 29 CFR 1910.67, covering vehicle-mounted elevating and rotating work platforms. The company is classified under NAICS code 517910, Other Telecommunications, and the cited location has 11 employees. No injury is documented in connection with this case. OSHA's own records classify the inspection as unprogrammed and related to another matter, a category that typically originates from a complaint or referral rather than a scheduled visit, though the public data does not disclose what specifically prompted it.
The Willful Citation: No Training at All
The most serious of the 12 citations, carrying $70,000 on its own, more than half the total penalty, was classified Willful under 29 CFR 1910.268(c). That provision requires employers to train employees in the precautions and safe practices the Telecommunications standard covers before they do the work it applies to, and to keep a signed certification record proving it happened. A Willful classification is OSHA's own determination that a violation came from intentional disregard of, or plain indifference to, a safety requirement, not simple negligence. The citation establishes that the required training and certification were missing. The public inspection data does not include a narrative explaining OSHA's specific reasoning for calling that gap intentional rather than negligent, beyond the fact that it covers the standard's foundational training requirement rather than a narrower technical lapse.
Eleven More Citations, Same Underlying Gap
The other 11 citations, all classified Serious, read like direct consequences of the missing training. Two cover the training requirement's own content: procedures for emergency situations, 29 CFR 1910.268(c)(2), and first aid training including artificial respiration, 29 CFR 1910.268(c)(3). The rest cover equipment and practice in the field: maintaining OSHA's required clearance from energized overhead power lines, 29 CFR 1910.268(b)(7) and 29 CFR 1910.268(j)(3); limiting aerial lift operation to trained employees and testing lift controls daily before use, 29 CFR 1910.67(c)(2)(ii) and (c)(2)(i); wearing a fall arrest or travel-restraint system while working from an aerial lift, 29 CFR 1910.67(c)(2)(v); not wearing pole climbers while working from an aerial lift, a combination the standard specifically prohibits, 29 CFR 1910.268(g)(2)(iv)(c); head protection rated for high-voltage contact, 29 CFR 1910.268(i)(1); daily visual inspection of vehicle-mounted equipment, 29 CFR 1910.268(j)(1)(i); and traffic-control measures near vehicular or pedestrian traffic, 29 CFR 1910.268(d)(1).
Contested, Not Yet Final
Harlan Community Television contested all 12 citations on August 13, 2026. No final order has been entered, so the $122,500 total, and the Willful classification itself, is not yet finalized. Both figures could change before the case resolves.
A Mostly Clean Record, Until Now
OSHA's inspection history for Harlan Community Television includes only one earlier case, opened in 1989 at the company's Harlan, Kentucky location. That inspection produced two Other-Than-Serious citations for ladder defects under 29 CFR 1926.450(a)(9) and 29 CFR 1926.450(a)(10), both carrying no penalty and both marked abated the same day the case closed. No other OSHA inspection or violation appears on record for the company in the 37 years between that case and this one. FCC public cable system filings describe a similarly named Harlan Community TV Corp as a longtime cable and internet provider serving Harlan County; this article relies on OSHA's own case record, which lists the inspected entity as Harlan Community Television Incorporated, and does not assume the two are the identical legal entity.