OSHA Establishment Search
Look up any company's OSHA violations and citations by name, state, or city, a free establishment search and citation lookup built directly from public federal enforcement data.
TYSON FRESH MEATS, INC.
MADISON, NE
| Inspections With Violations | 5 |
| Total Citations | 8 |
| Total Penalties | $42,225.00 |
| Most Recent Case | March 17, 2026 |
March 17, 2026 · Follow-up
OSHA case 348817594
29 CFR 1910.219(f)(1) · Serious · $16,550.00
29 CFR 1910.219(f)(1): Gear(s) were not guarded by a complete enclosure or by one of the methods specified in 29 CFR 1910.219(f)(1)(ii) and (f)(1)(iii): Employee(s) were exposed to caught-in hazards. This was documented on or about March 17, 2026, at 1200 Industrial Parkway, Madison, Nebraska. The employer did not ensure that the guard on the Jaw Puller machine on the Harvest Floor was secured to prevent employees from coming in contact with the sprocket and chain.
Final order entered July 14, 2026.
February 21, 2023 · Referral
OSHA case 346520430
29 CFR 1910.119(d)(3)(i)(b) · Other-Than-Serious · $7,000.00
29 CFR 1910.119(d)(3)(i)(B): The employer did not include all equipment that was part of the process on piping and instrument diagrams(a): Liquid injection isolation valve #03714 for Frick Booster Compressor #4 was not included on P&ID MA-03-73-042. This violation was last observed on or about March 15, 2023.
Final order entered August 25, 2023.
May 28, 2012 · Unprogrammed
OSHA case 334697588
29 CFR 1910.147(c)(6)(i)(a) · Serious · $5,000.00
29 CFR 1910.147(c)(6)(i)(A): The periodic inspection of the energy control procedure was not performed by an authorized employee other than the one utilizing the energy control procedure being inspected: Throughout the Facility: The employer failed to conduct a periodic inspection of the energy control procedures as outlined above. The employer is having a single authorized employee review the procedure and a management representative does a document review and final certification. The procedure is to be reviewed by two authorized employees; one will perform the lockout operation outline of the procedure while the second ensures the procedures accuracy.
Final order entered June 12, 2013.
29 CFR 1910.212(a)(1) · Other-Than-Serious · $2,000.00
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: In the circle drive area of the kill floor: The employer did not provide guarding to protect employees from multiple pinchpoints on the the circle drive machine in that the wheel created an ingoing pinch point as did the chute gates.
Final order entered June 12, 2013.
May 25, 2012 · Follow-up
OSHA case 334464138
29 CFR 1910.119(n) · Serious · $7,000.00
29 CFR 1910.119(n): The employer did not implement an emergency plan for the entire plant in accordance with the provisions of 29 CFR 1910.38. Employer did not implement and follow the facility emergency action and emergency response plans regarding ammonia evacuation levels and determining wind direction to prevent exposure, during an employee evacuation from an external ammonia leak. On or about May 24, 2012, multiple ham line/converting employees suffered ammonia exposure injuries from wind driven ammonia gas leaking from the facility roof area, while evacuating their work area.
Final order entered December 20, 2013.
29 CFR 1910.119(d)(3)(i)(b) · Other-Than-Serious · $4,675.00
29 CFR 1910.119(d)(3)(i)(B): The employer did not include all equipment that was part of the process on piping and instrument diagrams. Piping and instrument diagrams (P & IDs) for the facility ammonia refrigeration system were not updated to reflect all system components including, but not limited to: A) Gauges added to new lines for Vilter compressors #1, #2, and #7 in the compressor room. B) Valves #030138 and #030137 in lines for the 40 degree Suction Trap were not located in the positions indicated by the relevent P&ID.
Final order entered December 20, 2013.
29 CFR 1910.134(d)(1)(iii) · Repeat · $0.00
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards. Employee exposure levels to carbon dioxide in the Offal Pack room had not been evaluated. Inspection direct read monitoring indicated levels of carbon dioxide ranging from 14,600 to 14,900 parts per million. Tyson Fresh Meats, Inc. was previously cited at its Lexington, NE facility for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.134(d)(1(iii), which was contained in OSHA inspection number 314058975, citation number 1, item number 4, issued on April 11, 2011, and became a Final Order effective May 5, 2011.
Final order entered December 20, 2013.
May 25, 2012 · Unprogrammed
OSHA case 334636982
29 CFR 1910.119(d)(3)(i)(b) · Serious · $0.00
29 CFR 1910.119(d)(3)(i)(B): The employer did not include all equipment that was part of the process on piping and instrument diagrams. Piping and instrument diagrams (P&IDs) for the facility ammonia refrigeration system were not updated to reflect all system components including, but not limited to: A) Gauges added to lines for Vilter compressors #1, #2, and #7. B) Valves #030138 and #030137 in lines for the 40 degree Suction Trap were not located in the positions indicataed by the relevant P&ID. C) Valves and gauges for the ham plant recirculator, including PSVs #30058 & #30009, did not have labels/ID tags that corresponded with the relevant P&ID.
Final order entered December 20, 2013.
Potential Matches
Other locations on file under the exact same company name. OSHA News does not combine these with the facility above - a shared name is not proof of a shared company, so click through to judge for yourself whether a listing below is really the same business.
| City | State | Inspections | Most Recent |
|---|---|---|---|
| CityLOGANSPORT | StateIN | Inspections2 | Most RecentNov 18, 2025 |
| CityWATERLOO | StateIA | Inspections28 | Most RecentSep 24, 2025 |
| CityDAKOTA CITY | StateNE | Inspections3 | Most RecentJun 11, 2025 |
| CityPERRY | StateIA | Inspections10 | Most RecentJan 18, 2023 |
| CityEMPORIA | StateKS | Inspections1 | Most RecentNov 18, 2022 |
| CityCOLUMBUS JUNCTION | StateIA | Inspections1 | Most RecentOct 31, 2022 |
| CityGOODLETTSVILLE | StateTN | Inspections1 | Most RecentDec 14, 2020 |
| CityHOLCOMB | StateKS | Inspections10 | Most RecentMar 23, 2020 |
| CityHILLSDALE | StateIL | Inspections5 | Most RecentNov 1, 2019 |
| CityAMARILLO | StateTX | Inspections6 | Most RecentAug 3, 2019 |
| CitySHERMAN | StateTX | Inspections1 | Most RecentApr 23, 2019 |
| CityCOLUMBUS JCTN | StateIA | Inspections4 | Most RecentJul 16, 2013 |
| CitySTORM LAKE | StateIA | Inspections2 | Most RecentDec 6, 2011 |
| CityLEXINGTON | StateNE | Inspections6 | Most RecentJan 26, 2011 |
| CityDENISON | StateIA | Inspections4 | Most RecentSep 1, 2009 |
| CityJOSLIN | StateIL | Inspections2 | Most RecentMar 6, 2007 |
| CityKUNA | StateID | Inspections2 | Most RecentOct 4, 2005 |