OSHA Establishment Search
Look up any company's OSHA violations and citations by name, state, or city, a free establishment search and citation lookup built directly from public federal enforcement data.
THE PAVING MASTERS LLC
MONROE, NY
| Inspections With Violations | 1 |
| Total Citations | 4 |
| Total Penalties | $188,684.00 |
| Most Recent Case | March 23, 2026 |
March 23, 2026 · Referral
OSHA case 348827270
29 CFR 1926.651(j)(1) · Serious · $11,585.00
29 CFR 1926.651(j)(1): Adequate protection was not provided to protect employees from loose rock or soil that could pose a hazard by falling or rolling from the excavation face: a) Worksite, excavation area between the concrete foundation wall and the embankment wall: On or about March 23, 2026, employees preforming excavation work consisting of but not limited to controlling water in an area adjacent to an excavation embankment wall 28' to 75' in height, 2'-37' wide and a slope between 20°-85° exposed employees to struck-by and crushed-by hazards from falling and rolling cobbles, boulders, and collapsing material when working within 2'-15' of the unprotected embankment. The employer did not adequality provide excavation protection which could include special support systems or shield systems to protect from cave-ins. b) Worksite, excavation area between the concrete foundation wall and embankment wall: On or about April 15, 2026, employees performing site excavation consisting but not limited to drainage work in an area adjacent to an excavation embankment wall 28' to 75' in height, 2'-37' wide and a slope between 20°-85° exposed employees to struck-by and crushed-by hazards from falling trees, rolling cobbles, boulders, and collapsing material when working within 2-'15' of the unprotected embankment. The employer did not adequality provide excavation protection which could include special support systems or shield systems to protect from cave-ins. c) Worksite, excavation area between the concrete foundation wall and embankment wall: On or about June 2, 2026, employees performing site excavation consisting of but not limited to unapproved slope abatement work in an area adjacent to an excavation embankment wall 28' to 75', 2'-37' wide and a slope between 20°-85°exposed employees to struck-by and crushed by hazards from falling and rolling cobbles, boulders, and collapsing material when working within 2'-15' of the unprotected embankment. The employer did not adequality provide excavation protection which could include special support systems or shield systems to protect from cave-ins.
Final order entered October 28, 2026.
29 CFR 1926.651(k)(1) · Serious · $11,585.00
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions: a) Worksite, excavation area between the concrete foundation wall and the embankment wall: On or about March 23, 2026, employees performing excavation work to include but not limited to grading and clearing mud adjacent to an excavation embankment wall 28' to 75' in height, 2'-37' wide and a slope between 20°-85° exposed employees to struck-by and crushed-by hazards from falling and rolling cobbles, boulders, and collapsing material when working within 2'-15' of the unprotected embankment. This was due to runoff water from heavy rain or melting snow and ice. The employer did not provide the required daily inspection by a competent person for evidence of any situation that could result in a cave-in, failure of protective systems, or other hazardous conditions. b) Worksite, excavation area between the concrete foundation wall and the embankment wall: On or about April 15, 2026, employees performing site excavation work to include but not limited to moving material to an area adjacent to an excavation embankment wall 28' to 75' in height, 2'-37' wide and a slope between 20°- 85° exposed employees to struck-by and crushed-by hazards from falling and rolling cobbles, boulders, and collapsing material when working within 2'-15' of the unprotected embankment as it was not protected from the runoff water from heavy rain and ground water seepage. The employer did not provide the required daily inspection by a competent person for evidence of any situation that could result in a cave-in, failure of protective systems, or other hazardous conditions. c) Worksite, excavation area between the concrete foundation wall and the embankment wall: On or about June 2, 2026, employees performing site excavation work including but not limited to unapproved slope abatement adjacent to an excavation embankment wall 28' to 75' in height, 2'-37' wide and a slope between 20°-85° exposed employees to struck-by and crushed-by hazards from falling and rolling cobbles, boulders, and collapsing material when working within 2'-15' of the unprotected embankment as it was not protected from the runoff water from heavy rain or ground water seepage. The employer did not provide the required daily inspection by a competent person for evidence of any situation that could result in a cave-in, failure of protective systems, or other hazardous conditions.
Final order entered October 28, 2026.
29 CFR 1926.652(a)(1) · Willful · $165,514.00
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c). a) Worksite, excavation area between the concrete foundation wall and the embankment wall: On or about March 23, 2026, employees performing excavation work to include but not limited to removing mud in an area adjacent to an excavation embankment wall 28' to 75' in height, 2'-37' wide and a slope between 20°-85° exposed employees to struck-by and crushed-by hazards from falling and rolling cobbles, boulders, when working within 2'-15' of the unprotected embankment. The employer failed to provide proper excavation protections to include sloping and shoring. b) Worksite, excavation area between the concrete foundation wall and the embankment wall: On or about April 15, 2026, employees performing excavation work to include but not limited to installing drainage in an area adjacent to an excavation embankment wall 28' to 75' in height, 2'-37' wide and a slope between 20°-85° exposed employees to struck-by and crushed-by hazards from falling and rolling cobbles, boulders, when working within 2'-15' of the unprotected embankment. The employer failed to provide proper excavation protections to include sloping and shoring. c) Worksite, excavation area between the concrete foundation wall and the embankment wall: On or about June 2, 2026, employees performing excavation work to include but not limited to methods not included in the submitted engineered plan for slope abatement in an area adjacent to an excavation embankment wall 28' to 75' in height, 2'-37' wide and a slope between 20°-85° exposed employees to struck-by and crushed-by hazards from falling and rolling cobbles, boulders, when working within 2'-15' of the unprotected embankment. The employer failed to provide proper excavation protections to include sloping and shoring.
Final order entered October 28, 2026.
29 CFR 1926.652(b)(4)(i) · Willful · $0.00
29 CFR 1926.652(b)(4)(i): Sloping or benching for excavations greater than 20 feet deep were not designed by a registered professional engineer: a) Worksite, excavation area between the concrete foundation wall and the embankment wall: On or about March 23, 2026, employees performing excavation work to include but not limited to removing mud in an area adjacent to an excavation embankment wall 28' to 75' in height, 2'-37' wide and a slope between 20°-85° exposed employees to struck-by and crushed-by hazards from falling and rolling cobbles, boulders, when working within 2'-15' of the unprotected embankment. The employer failed to provide proper engineered plan. b) Worksite, excavation area between the concrete foundation wall and the embankment wall: On or about April 15, 2026, employees performing excavation work to include but not limited to installing drainage in an area adjacent to an excavation embankment wall 28' to 75' in height, 2'-37' wide and a slope between 20°-85° exposed employees to struck-by and crushed-by hazards from falling and rolling cobbles, boulders, when working within 2'-15' of the unprotected embankment. The employer failed to provide proper engineered plan. c) Worksite, excavation area between the concrete foundation wall and the embankment wall: On or about June 2, 2026, employees performing excavation work to include but not limited to unapproved slope abatement in an area adjacent to an excavation embankment wall 28' to 75' in height, 2'-37' wide and a slope between 20°-85° exposed employees to struck-by and crushed-by hazards from falling and rolling cobbles, boulders, when working within 2'-15' of the unprotected embankment. The employer failed to provide proper engineered plan.
Final order entered October 28, 2026.