OSHA Establishment Search

Look up any company's OSHA violations and citations by name, state, or city, a free establishment search and citation lookup built directly from public federal enforcement data.

TEXTRON AVIATION INC

WICHITA, KS

Inspections With Violations1
Total Citations3
Total Penalties$33,100.00
Most Recent CaseFebruary 25, 2025

February 25, 2025 · Fatality/Catastrophe

OSHA case 348061458

29 CFR 1910.134(i)(1)(ii)(a) · Serious · $16,550.00

29 CFR 1910.134(i)(1)(ii)(A): Breathing air did not contain 19.5-23.5% oxygen (volume/volume): On or about February 24, 2025, in Plant III, employee(s) were exposed to asphyxiation and death in that the compressed air system did not meet requirements for Grade D breathing air in the following instance: 1) In Paint Booth 5 the supplied air hood had oxygen levels recorded at 5.3% concentration. 2) In Paint Booth 7 the supplied air hood had oxygen levels recorded at 7.8% concentration 3) In the Carousel/Prime Booth, the supplied air hood had oxygen levels recorded at 5.3% concentration.

Final order entered July 1, 2025.

29 CFR 1910.134(i)(8) · Serious · $16,550.00

29 CFR 1910.134(i)(8):An asphyxiating substance was introduced into breathing air lines: On or about February 24, 2025, at the Paint Booth #5 in Plant III, employee(s) were exposed to respiratory health hazards in that the piping configuration and the open compressed air ball valve of the Autoclave #10, connecting the nitrogen and compressed air systems, allowed the introduction of nitrogen gas into the breathing airlines used at the Paint Booth #5, asphyxiating an employee and also exposing employees at Paint Booth #7 and the Carousel/Prime Booth.

Final order entered July 1, 2025.

29 CFR 1910.134(i)(5)(iv) · Other-Than-Serious · $0.00

29 CFR 1910.134(i)(5)(iv):The tag containing the most recent change to the sorbent beds was not maintained at the compressor: Compressor used for breathing airline system did not have a tag showing most recent change date of the sorbent beds and the signature of the person authorized by the employer to perform the change at the following instances: 1) Sullair LS-20S located at Plant III 2) Sullair DSP-75AT6N-M125 (AC-1) Maintenance No. 303080 located at Building 46 3) Sullair DSP-75AT6N-M125 (AC-2) Maintenance No. 303081 located at Building 46 4) Sullair V130 DS Maintenance No. 10048198 located at Plant IV 5) KAISHAN Krof 200 Maintenance No. 46898 located at Plant IV 6) Sullair Maintenance No. 300420 located at Plant I 7) Sullair V-320TS Maintenance No. 10046440 located at Plant I 8) Sullair Maintenance No. 301431 located at Plant I

Final order entered July 1, 2025.