What Happened

At 11:43 a.m. on February 24, 2025, an employee of Textron Aviation Inc was spray painting aircraft parts in a paint booth at the company's east Wichita campus, wearing a supplied-air respirator. Nitrogen backflowed into the breathing air system, displacing oxygen in the line he was breathing from. He was asphyxiated and died at the scene. Local reporting identified him as Rocky Baldwin, 61.

What OSHA Found

OSHA issued three citations for a combined $33,100. The central citation, classified Serious at $16,550, was under 29 CFR 1910.134(i)(1)(ii)(A), the requirement that breathing air supplied to a respirator meet at least Grade D quality, uncontaminated by other gases. A second Serious citation, also $16,550, was issued under 29 CFR 1910.134(i)(8), covering the minimum air-flow and pressure requirements for a supplied-air respirator system. A third citation under 29 CFR 1910.134(i)(5)(iv), covering labeling of breathing air couplings so they can't be cross-connected to an incompatible gas supply, was classified Other-Than-Serious with no monetary penalty. None of the three were contested. A final order was entered July 1, 2025.

The Respirator That Became the Hazard

A supplied-air respirator is meant to protect a worker from the hazards of the job itself, in this case, paint fumes. The citations here describe the opposite failure: the air system meant to keep him safe let nitrogen into the line he was breathing from, displacing the oxygen without warning. Our guide to OSHA's first aid and emergency-response requirements covers a related but distinct duty, what has to be on hand to respond once something goes wrong; this case is about preventing the breathing air itself from becoming the thing that kills someone.

Company History

OSHA's records show a second inspection at a Textron Aviation Inc. facility in Wichita, Kansas, opened August 22, 2025, roughly six months after this fatality, with no citations on record from that inspection as of this writing.